ALL >> Education >> View Article
Hp0-s45 Preparation Kits

Question: 1
A customer has an HP ProLiant DL380 Gen9 server with one processor that has a large RAID 5 SAS Array configured on a P440ar storage controller with a hot spare. During the rebuild process, a second SAS drive failed.
What should the integrator do to help prevent this problem from reoccurring?
A. Configure a higher Rebuild.
B. Priority Install a second hot spare disk drive.
C. Install more memory in the server.
D. Use the integrated B140i controller.
Answer: D
Question: 2
A system integrator installed an operating system on an HP ProLiant Gen9 Server.
Which operating system can be used with UEFI Boot Mode?
A. VMware ESXi 5.5
B. Windows Server 2008 32-bit
C. Citrix XenServer 6.0
D. Windows Server 2003 64-bit
Answer: A
Question: 3
A customer with ProLiant Gen9 based servers needs to add external storage to some of the servers.
Which component should the integrator recommend?
A. 12GB SAS Expander Card
B. HP Smart Array P841
C. HP Smart Array P440ar
D. HP IO Accelerator
Answer: ...
... C
Question: 4
What is a benefit of using 20Gb FlexFabric Converged network adapter (CNA) for the BladeSystems?
A. It allows support tor RDMA over Converged Ethernet (RCOE) when the HP 6125XLG is used in conjunction with the FlexFabric adapter.
B. It delivers 10Gb performance per port with an aggregate 20Gb in a dual-port adapter.
C. The adapter streams converge 10GbE and 16Gb storage simultaneously over the same 20GD port.
D. Performance is delivered through multiple 2/10Gb ports using multiple adapters in a teamed fashion.
Answer: A
Question: 5
An integrator is installing an HP ProLiant DL380 Gen9 server with an H240ar controller installed. The integrator needs to install a total of 24 SFF Drives.
Which additional task must the integrator perform to meet the requirements?
A. Add an HP 12 GB SAS Expander Card cabled to the H240ar and cabled to two SFF backplanes.
B. Ada an SFF cable and an SFF backplane to the H240ar.
C. Add two more H240ar controllers with 8 SFF drives attached to each controller.
D. Add a rear drive cage backplane and cable it to the M240ar.
Answer: C
Add Comment
Education Articles
1. Can Ielts Academic Be Used For Immigration?Author: lily bloom
2. A Course On The Importance Of Upskilling At The College Level
Author: stem-xpert
3. Global Clinical Trials: Unveiling India’s Booming Market Outlook For 2025!
Author: Aakash jha
4. The Power Of Micro-influencers: Why They Matter More Than Ever
Author: dev
5. Digital Marketing Course In Dadar
Author: Sanchi
6. The Best Sre Course Online In India | Sre Training
Author: krishna
7. Top Google Cloud Ai Training In Chennai - Visualpath
Author: visualpath
8. Best Dynamics 365 Business Central Online Training - Hyderabad
Author: Susheel
9. The Best Data Engineering Course In Hyderabad - 2025
Author: naveen
10. Microsoft Dynamics 365 Course In Hyderabad | D365 Training
Author: Hari
11. Top Salesforce Marketing Cloud Training In Ameerpet
Author: Visualpath
12. Top Snowflake Course In Ameerpet | Snowflake Online Training
Author: Pravin
13. List Of Top Online Ma Colleges In India
Author: Study Jagat
14. Scrum Master Training In Bangalore | Scrum Master Classes
Author: visualpath
15. Mendix Online Training | Mendix Online Certification Course
Author: himaram