ALL >> Business >> View Article
Important Parts Of A Centrifugal Fan
Variable pitch axial flow fans are special type of axial fans with adjustable impeller blades that are built to handle broad operating ranges in critical industrial applications. These fans include an internal mechanism that can automatically adjust blade angle while the fan rotor is in motion. Due to their compact design and high efficiency, most of the variable pitch axial flow fans find applications in the thermal power stations where fresh air is needed (forced draft) or process involving high temperatures such as in boilers (induced draft). These type of fans are proven to have negligible loss in power at the output and hence they are also used in pulverizer air fans and flue gas desulphurization (FGD) applications.
Among the single and multi-stage designs, the two stage variable pitch axial fans with variable blade pitch angle find wide usage in many industrial processes. It is also simple to maintain the fan system as most of the critical parts such as rotor - consisting of the impellers, the main bearing assembly and the propeller blades are isolated as separate units for easy accessibility.
Types of variable ...
... pitch axial fans:
Depending on the number of propellers present on the shaft the variable pitch axial fans are mainly divided into two types.
Single stage variable pitch axial fan
Single stage variable pitch axial fan consists of a single propeller on the shaft.
This system is capable of delivering high volumes of about 1000 m3/s at pressures up to 15 kPa.
Two stage variable pitch axial fan
Two stage variable pitch axial fan consists of two propellers mounted on a single shaft and the propellers are separated by guide vanes.
This type of fan can deliver high volumes relatively at high pressure when compared to single stage system. (1000 m3/s at 30kPa.)
As this system consists of two propellers in a single unit, it has reduced shaft length with minimum overall dimension resulting in compact system. This rigidity in spacing adds as an advantage in eliminating the problems of resonance and vibration at the work place.
Working of variable pitch axial fans:
The main parts that are used in varying the pitch of axial fan are hub spring, diaphragm, blade shafts, rotary air/gas joint and valve positioner.
When air/gas stream falls on the propeller blades, it tries to rotate the blades. The hub spring creates a movement which helps to rotate the blade in opposing direction. The rotation of blades due to air/gas stream, exerts pressure on the diaphragm to oppose the hub spring movement and this creates a variation in blade pitch. The amount of pressure exerted will determine either the amount of air/gas flow or a complete change in the direction of air/gas flow.
The basic design and operation is similar for both single and double stage variable axial fans except the later one contains two propellers.
Comparison - Axial Fan vs Variable Axial Fan
Output volume
Variable pitch axial fans with varied blade angles can deliver higher volume rates when compared to fixed blades of normal axial fans.
Energy consumed
As the air/gas pressure is controlled automatically by the fan by varying the pitch of propeller, there is no need for an throttling device which consumes extra energy for its working. As the stress acting on the blades is also less, the total load acting on the motor remains constant. In case of fixed axial blades a throttling device is to be supplied to control flow pressure, which consumes energy and the blades of the propeller are subjected to high stress enforcing extra load on the motor.
Variable pitch axial flow fans are specially designed to serve specific requirements of industrial applications because of their instantaneous blade adjustment capability, higher efficiency and sustainability for higher temperatures.
Reitz India, a global leader in fan technology, has served the needs of various industries with thousands of centrifugal fan installations not only in India but in Middle East, East Africa and South East Asian countries as well. Reitz has incorporated latest technology in FD fan and PA fan design and fabrication to provide energy efficient and cost effective solutions with high industrial standards.
Add Comment
Business Articles
1. Transform Your Uk Outdoor Spaces: Patios And Paving Makeovers For Homes, Businesses, And High-risesAuthor: Vikram Kumar
2. Semantic Seo Strategies: Topic Clusters Vs. Isolated Pages In 2026" – Explains Knowledge Graphs For Better Ai Visibility
Author: Vikram Kumar
3. Elegant Yet Affordable: A Complete Guide To Muslim Wedding Cards And Wedding Cards Under Rs 20
Author: Vishakha Collections
4. Panama License For Seafarers | Your Complete Guide Through The Panama Mission India
Author: Panama Mission India
5. Best Driveway And Patio Surfacing Options: Resin, Block Paving, And Tarmac For Residential And Commercial Properties
Author: Vikram Kumar
6. Best Online Charging Systems For Telcos Driving Real-time Revenue Control
Author: Kevin
7. The Role Of A Digital Business Card - Explained
Author: Angus Carruthers
8. Simple Guide To Kaal Sarp Dosh Nivaran Puja And Rahu Ketu Pooja Benefits
Author: Pandit Umesh Guruji
9. Innovative Plastic And Utility Solutions Supporting Modern Infrastructure In New Zealand
Author: Sreka
10. Transform Your Space With Indoor Water Features
Author: Aqua Light
11. Strengthening Digital Trust With Enterprise Certificate Management And Iot Security Platform
Author: Elly Smith
12. Plots In Goa: The Ideal Investment For Lifestyle
Author: santwhitelisted
13. Springs Exporters In India
Author: Jayesh Shah
14. Kyc Bpo Projects: A Complete Guide For Modern Businesses
Author: naina
15. Imperial Security London Security Services
Author: Imperial Security






