ALL >> General >> View Article
Industrial Regenerative High Pressure Blowers
Regenerative pressure blowers are ideal for moving large volumes of air at low pressures or vacuums. Unlike positive displacement compressors and vacuum pumps, they pressurize air through a nonpositive displacement method. Typical regenerative blower applications include sewage aeration, vacuum lifting, vacuum packaging, pneumatic conveying, concrete aeration, pond aeration, vacuum tables, drying, dust/smoke removal, air sparging, and chip removal.
Side Channel blowers are oilless and have no complicated intake/exhaust valving. Most can be mounted in any plane and, with dynamically balanced impellers, generate little vibration. Because they are nonpositive displacement compressor/vacuum pumps, they discharge air that is clean and pulsation free, which are important considerations for today's plant instruments and controls.
Regenerative blowers operate as a multistaged compressors. Each blade-to-blade regeneration stage results in a slight pressure increase. Total pressure rise from air entry to discharge yields a continuous operating pressure up to 300-in. w.g. (11 PSIg) or a vacuum to 14-in. Hg with continuous ...
... flows to more than 1400 scfm (Fig. 3).
Of all air handling equipment, regenerative blowers are probably the least understood. However, when system parameters fall within their range, they can be among the most cost-effective methods for moving air and producing pressure or vacuum.
Regenerative blowers are sometimes called side channel blowers or ring compressors, terms that refer to their physical construction. They can be direct or belt driven. In direct drives, the impeller is mounted on an electric motor shaft. The number, size, and angle of the blades on the impeller determine pneumatic performance as well as the relationship between the impeller and housing. Some blowers have rather flat performance curves while others have steep ones.
The impeller spins within a housing with an inboard and outboard channel. It is from this configuration that the name side channel blower is drawn. As the impeller blades pass the inlet port, they draw air in. The impeller rotation pushes air outward and forward into the channels. The air then returns to the base of the blade. As the impeller spins, the process repeats. This regeneration gives the blower its pressure/vacuum capabilities.
Most blowers are single stage: air travels around the blower housing once and is discharged. Two-stage regenerative blowers can provide almost twice the pressure or vacuum of single-stage units. In a single-impeller, two-stage unit, air makes one revolution around the front side of the impeller. Then, instead of being discharged, the air is channeled to the backside of the impeller through internal porting. Air then makes another revolution around the backside of the impeller before it is discharged. Other two-stage configurations are also available, including designs that use two separate impellers in one housing or two impellers and housings.
Among the major benefits of a regenerative blower is its lack of maintenance and monitoring requirements. The impeller is the only moving part and is wear free and does not come in contact with the housing channels. Self-lubricated bearings are the only parts that wear.
The majority of blower failures are caused by improper installation or operation. Regenerative blowers have close internal clearances between the impeller and housing. It is important to prevent foreign material from entering that space. Ingested debris wedging between the impeller and housing can cause the blower to lock up and lead to a catastrophic failure. A blower should always be equipped with an intake filter. A 10-micron size is usually adequate. Filters must be kept clean. A blocked filter will starve flow.
Over-pressurization can also cause deadheading (zero airflow through the blower) and catastrophic failure. Some blowers tolerate deadheading, but other models (typically those above 1 hp) must have air passing through them for cooling. If air does not pass through the blower, heat builds up in the impeller causing it to expand at a faster rate than the housing. Eventually the impeller locks up with the housing and the blower fails. A relief valve prevents overpressurization and deadheading conditions and allows air to pass through the blower.
Additional information can be found at the Fans Mall Company web site http://barryfan.net
Oleg Tchechel
Industrial Equipment Engineer
Fans Mall Co.
nis@primus.ca
http://www.barryfan.net/industrial-fans.html
http://www.barryfan.net/industrial-blowers.html
Add Comment
General Articles
1. Magento Developers Melbourne: Your Trusted Partner For Magento Web DevelopmentAuthor: themerchantbuddy
2. How Can E-commerce App Development Help Your Business?
Author: Comfygen
3. The Best Baby Cot Mattress For Summer In Australia: Keep Your Baby Cool And Comfortable !
Author: Milari Organics
4. How Might An Amazon Fba Prep Service Center Help You Streamline Your Business?
Author: 3pshipping6
5. Reviving Artisanal Craftsmanship – Why Handmade Products Matter More Than Ever
Author: Chaitanya Kumari
6. What To Look For In A New York Labor And Employment Law Firm
Author: jewellansing792
7. 50 Years Of Long-lasting Performance
Author: Busch Vacuum Solutions
8. Optimize Healthcare Revenue Cycle: Strategies For Financial Success
Author: Albert brown
9. Offres Exclusives Pour Vos Voyages En Inde Du Nord — Économisez Jusqu’à 30% — Réservez Dès Maintenant!
Author: yatika
10. 200-hour Weekend Yoga Teacher Training Course (yttc) In Bengaluru: A Pathway To Mastery In Yoga
Author: Yogakulam Academy
11. Understanding Patient Behavior: The Importance Of Market Research In Healthcare Marketing
Author: Adomantra
12. Ensuring Safety And Privacy: The Advantages Of Close Protection Services In Dubai
Author: Shancy
13. Thermodynamic Steam Traps: A Compact Solution For Maximum Performance
Author: David John
14. Best Accounting Service In California – Mj Financials
Author: maria jeffery
15. Best Astrologer In Hosahalli
Author: Pandith Keshav Das