High Pressure Blowers Systems By Buffalo Fan Co

Profile Picture
By Author: Oleg Tchetchel
Total Articles: 31
Comment this article
Facebook ShareTwitter ShareGoogle+ ShareTwitter Share

Buffalo Fan Co. has introduced lately blowers-in-series high pressure systems to achieve static pressure, previously unachievable by single stage centrifugal blowers.

Series and parallel connected blower installations are often used to meet performance ranges beyond normal single stage blower capacities. For systems that require high ststic pressure, and especially high pressure TOGETHER with high temperature (where standard multi stage, positive displacement, screw, or regenerative type blowers can not be used) series of single stage centrifugal blowers can be used. Many times additional blower in the system can be advantageous. For instance, where two blowers are operating in series and one breaks down, the other may be able to "limp" the system along while the necessary maintenance is performed. Having on blower continue in operation can often allow limited production while the other is being repaired. Also, there are cases where having one blower continue in operation could prevent or at least minimize system or equipment damage from such things as high temperature ot contaminated airstreams.

Another advantage ...
... of blowers in series is that of the availbale space. If system must be expanded and increaases the CFM requirements, the allotted space for the original blower may not be large enough for a single large blower, but might be large enough to istall two smaller blowers in series to obtain the necessary pressure.

One potentail advantage for series operation is the likehood of initial cost savings. Although each case must be evaluated individually, it is often more economical to select two "smaller" blowers with their respectice smaller motors and drives than to select one "larger" blower to do the job.

Series connected blowers are those which have the outlet of the one blower exhausting into the inlet of another blower. By connecting blowersa in such a manner, high static pressures can be attained. This is accomplished as the second blower adds its pressure capability to the system, increasing the capacity beyond the capabilities of the first blower.

Ideally, two identical blowers installed in series would result in the same CFM at the outlet of the second blower as the inlet of the first one, and nearly twice the static pressure as that rated for either blower alone. However, some variation will result in both air flow and combined pressure because of the tendency of air to compress under pressure. A good understanding of how atnoshperic pressure and absolute temperature affect density is required. Both of these factors are involved in the proper selection of blowers. Density is directly proportional to atmospheric pressure and is inversely proportional to absolute temperature (degrees Rankine).

Caution is necessary in selecting blowers for series installtion. It is generally accepted that most pre-engineered blowers are capable of withstanding twice their catalog rated static pressure. In other words, where two blowers are installed in series the second blower housing should withstand the higher pressure. There is, however, a need for concern when the combined pressure exceeds twice the rated static pressure for one blower. In series applications involving three or more blowers, or in any system in which positive or negative pressure exists prior to the consideration of the blowers, special housing reinforcement may be necessary.

For additional information please refer to Buffalo Fan Co. web site http://www.buffalofan.com/custserv.html.

Oleg Tchetchel
Industrial Process Specialist
Buffalo Fan Co.
http://www.buffalofan.com/faninquiry.html
http://www.buffalofan.com/silencer.html

Total Views: 191Word Count: 537See All articles From Author

Add Comment

Education Articles

1. Top Paying Careers In The Business Analytics Sector
Author: Sarika

2. Study In Italy 2025: Free Consultation With Videsh Consultz
Author: Videsh

3. Data Science For Urban Air Quality Monitoring
Author: Gour

4. Tosca Training Institute In Hyderabad | Tosca Testing Online Training
Author: Susheelvisualpath

5. Deep Dive Into Fellowship In Reproductive Medicine
Author: Medline Academics

6. Devops Training In Hyderabad | Devops Training Institute In Ameerpet
Author: visualpath

7. Top Medical Universities In Turkey For Indian Students Pursuing Mbbs
Author: Mbbs Blog

8. Pursue Your Dream: Mbbs In Romania—affordable, World-class Education For Indian Students
Author: Mbbs Blog

9. Comprehensive Guide For Indian Mbbs Aspirants: Food And Hostel Facilities At Top Medical Universities In China
Author: Mbbs Blog

10. Exploring Non-traditional Pathways To Education: Online Courses And Beyond
Author: Briggate Educational Consultants

11. Best Seo Coaching & Online Classes For Learning Seo In 2024 | Captivate Designs
Author: Nicole McCullum

12. Canada Implements Temporary Cap On Study Permits To Address Housing Crisis
Author: luminarytimes

13. Why Switzerland Is The Top Destination For Studying Abroad: Insights From Our Education Fair
Author: Videsh

14. Bennett University: A Top Choice For Mba In Delhi
Author: Rohit Ridge

15. Azure Devops Training In Hyderabad | Azure Devsecops Training
Author: Renuka

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: