123ArticleOnline Logo
Welcome to 123ArticleOnline.com!
ALL >> Health >> View Article

Roof Ventilators For Building Ventilation

Profile Picture
By Author: Oleg Tchetchel
Total Articles: 55
Comment this article
Facebook ShareTwitter ShareGoogle+ ShareTwitter Share

Canada Blower Co. makes now a truly reversible (exhaust and supply roof fan for general ventilating.

The Type CBRE recirculators are designed for use in commercial and industrial applications where there is sufiicient ceiling height to create a temperature differential between the floor and the ceiling. These applications include factories, warehouses and large commercial buildings.

CBRE Roof Recirculators function as regular power roof ventilators in warmer weather and as an energy-saving recirculation air system in cold weather. Each unit is equipped with a reversible fan that distributes warm ceiling air thoughout the plant and reduces the builing's heating requirements. With a flip of a switch it can function as a conventional roof ventilator. There are two unit types: 1) for exhaust and recirculation; 2) for exhaust, supply and recirculation.

Available fan wheel sizes are from 24" to 60", performances: to 50,000 CFM @ 1/2" WG.

The reversible propeller incorporates specifically engineered airfoil sections and hub size for optimal efficiency and physical strength. Alternate adjustable pitch propeller ...
... blades are turned 180 degrees to one another and a double orifice is attached to the fan panel.

Type HS PRVs reliably extract large volumes of hot gases and smoke regardless of building configuration, location and weather conditions. They withstand high temperatures for long periods of time.

Another reliable ventilation system that can operate during a fire is Canada Blower Type HS Heat and Smoke Roof Ventilator. It prevents smoke logging, allows people to escape quickly, minimizes damages to property and contents and enables firemen to attack the fire without hindrance. These power roof ventilators have the added advantage of providing normal day to day ventilation and in many cases can also be fitted with duct work for use in multi storey buildings.

The concept of venting smoke and heat was first outlined by Industrial Risk Insurers (IRI). Use of powered ventilation could eliminate the problems experienced with gravity vents. Specially designed roof mounted exhaust fans would mechanically vent heat and smoke under emergency fire conditions.

The unique Type HS power roof ventilators provide a solution for emergency heat and smoke venting that is dependable under the most extreme circumstances.

All critical components of HS PTV that exposed to the airstream are ferrous construction to withstand high temperature conditions. These heavy gauge materials prevent warping of fan parts and malfunction at high temperatures. This also insures years of trouble-free service in normal daily operation of the PRV.

Belt and bearings are protected from the air stream by enclosing them in a ventilated tube. Design of HS fan incorporates a heat slinger/impeller. It isolates the fan bearings from damaging heat and draws cooler outside air through the motor compartment and over the belt and bearings. A spring load, fusible link activated device automatically opens dampers when temperature at the fan reaches 165 F. Thei enables the fan to function as a gravity ventilator prior to powered operation.

Type HC Power Roof Ventilators have been tested to operate:

- conituously at 650 F;
- 3 Hours at 800 F;
- 1.5 Hours at 1000 F;
- 1/2 Hour at 1,200 F.

Additional information can be found at the Canada Blower Co. Co. web site http://canadianblower.com/ahu/index.html.

Oleg Tchetchel
Industrial Air Process Designer
Canada Blower Co.
http://www.canadianblower.com/hvac/index.html
http://www.canadianblower.com/index.html

Total Views: 260Word Count: 521See All articles From Author

Add Comment

Health Articles

1. Hypertensive Cardiovascular Disease: Understanding The Connection Between High Blood Pressure And Heart Health
Author: Dr Siam Al Mobarak

2. Best Cataract Surgery In Badlapur: Your Guide To Optimal Eye Care
Author: Anil Eye Hospital

3. Achieve Your Dream Body With Brazilian Butt Lift, Liposuction, And Tummy Tuck Surgery In Chicago
Author: CIPlastic

4. Top Lifestyle Changes To Prevent Chronic Joint And Back Pain
Author: Adam Vital Hospital

5. Facelift For Different Age Groups: Best Options In Your 40s, 50s, And Beyond
Author: Dr.Sajan

6. Reduce Risk Of Heart Problems With Weight Loss
Author: Alexis Pelloe

7. Comprehensive Eye Examinations In San Antonio: Ensuring Optimal Vision Health
Author: Sharron Acosta

8. Major Breakthrough: Five-year Survival In Nsclc Patients Treated With First-line Pembrolizumab
Author: MD Newsline

9. Comprehensive Eye Examinations In Torrance: What To Expect
Author: East West Eye Institute

10. What Are Dental Implants Procedures ?
Author: Camas Periodontics

11. Why Cosmetic Dentistry Might Be Right For You? Feel Good To Smile And Be Confident In Every Facial Expression
Author: Vikram Vasisht

12. Wisdom Tooth Often Needs Extraction….because!
Author: Vikram Vasisht

13. How To Store Bulk Weed Properly To Maintain Freshness
Author: Jose Henry

14. Safeguarding Healthcare: Essential Cybersecurity Strategies For Protecting Patient Data
Author: Triyam Inc

15. Building A Foundation For Your Child’s Oral Health
Author: Ansley Colton

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: