ISO 17025 is an international standard for laboratory performance, ensuring the accuracy and reliability of results in calibration and testing. An important part of maintaining compliance is conducting regular internal and external reviews of measurement systems. The following ISO 17025 audit checklist provides detailed guidance for auditors to assess the key elements of measurement under the standard.

General Requirements for Calibration
• Scope of Accreditation: Verify that calibration performed by the laboratory matches its scope of accreditation. Confirm that the equipment listed is within its calibration scope by the laboratory.
• Laboratory Environmental Conditions: The laboratory environment (temperature, humidity, dust, vibration) should be suitable for performing the calibration activities.
• Personnel Competency: Ensure that calibration undertaken is carried out by trained and suitably qualified cleanness with experience in carrying out calibration activities.

Written Procedures and Work Instructions
• Calibration Procedure: Ensure that, for all of the equipment and instruments ...
... used, there exist written, up-to-date procedures for calibration that are in accordance with the ISO 17025 audit checklist and include the details of measurement methods, calibration standards, and tolerances.
• Control of Documentations: All records for calibration must be maintained properly, accessible, and meet the requirements for document control, including revision history and approval processes.

Measurement Traceability
• Calibration Standards: Ensure that all calibration standards being used in the laboratory are traceable to national or international standards. Ensure that those calibration standards are recalibrated in regular intervals and records of calibration are available.
• Measurement Uncertainty: Is the measurement uncertainty properly assessed and documented for all calibrations? ISO 17025 calibration laboratories have to consider and report the uncertainty related to every measurement.

Equipment and Instrument Maintenance
• Calibration and Maintenance of Equipment: Check all the equipment for regularly scheduled calibrations and maintenance. Read maintenance records and check if the instruments are still working within set limits.
• Verification of Calibration Intervals: Validate that the set intervals for calibration are based on the manufacturer's user manual, risk assessment, and historical performance data.

Non-Conformance & Corrective Actions
• Non-Conformance Record: Check the non-location of the non-conformance in any calibration activity, documented promptly and assessed promptly.
• Corrective and preventive actions: Review the effectiveness of corrective action in response to discrepancies noted during calibration with the necessary follow-up to aid continuous improvement.

Calibration Reporting
• Calibration Certificates: Each calibration certificate shall be included with all pertinent details such as equipment identification, calibration results, measurement uncertainties, and traceability to national/international standards.
• Reporting Format: Check that all reports are clear and consistent and contain all relevant data necessary for complete traceability and repeatability of results.

Internal Audit and Continuous Improvement
• Internal Audit Process: Confirm to the extent possible that the laboratories conduct an internal audit now and then to keep themselves aligned with ISO 17025. Review audit reports and follow up on corrective action.
• Management Reviews: Check whether management reviews are conducted regularly to evaluate the validity of calibration operations and identify potential improvements.

The normal ISO 17025 audits are quite important for maintaining the integrity of a laboratory's calibration process. This checklist provides a framework for auditors to ensure that the labs can achieve a high standard of accuracy, reliability, and compliance, which leads to consistent and trustworthy calibration results. Regular audits carry on adherence to international standards for competence and quality.

Source Link: https://certificationauditchecklist.wordpress.com/2024/12/23/comprehensive-iso-17025-audit-checklist-for-calibration-processes-and-compliance/

Total Views: 37Word Count: 522See All articles From Author

Add Comment

Business Articles

1. Repair And Maintenance Guide For Garden Fencing
Author: Vikram kumar

2. Lucintel Forecasts The Global Palatant Market To Grow With A Cagr Of 5% From 2024 To 2030
Author: Lucintel LLC

3. Choosing The Right Gas Regulator In Florida: A Complete Guide
Author: Technico

4. Why Deer Park Learners Trust Local Driving Instructors
Author: Aintree Driving School

5. How To Properly Install And Uninstall Your Air Conditioner System With A Low Budget
Author: Neha Jain

6. What Is The Role Of Pdca In Iso 50001?
Author: William Charles

7. Step-by-step Instructions On How To Generate Inventory Reports Quickbooks?
Author: Jack Edwards

8. How To Track Employee Work Hours Efficiently With Trackhr
Author: TrackHr App

9. From Grounded To Global: 4 Ceos Rewiring India’s Aviation Sky
Author: Skyone

10. The Role Of Automation In Modern Cloud Migration Methodology
Author: Netscribes

11. Master Photo Retouching | Steps To Become A Photo Editing Expert
Author: ukclippingpath

12. Great Dependability And Performance Are The Reasons For Extensive Use Of Hydro Pneumatic Press
Author: David Camp

13. Best Lasik Eye Surgery For A Spectacle-free Life
Author: Anil Eye Hospital

14. Industrial Oven Manufacturers In Coimbatore
Author: Heatcon Sensors

15. Plumbing In North Salt Lake: Your Guide To Reliable Services
Author: Brown Jones

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: