Variable Primary Flow Chilled Water System

Profile Picture
By Author: Climaveneta India
Total Articles: 27
Comment this article
Facebook ShareTwitter ShareGoogle+ ShareTwitter Share

The advancement in technology for HVAC controls applied to chilled-water systems makes it possible to reduce the environmental impact and operating costs.
Chillers are the biggest power consuming equipment in the chiller system but other equipment such as pumps, cooling towers and or dry coolers, Cooling tower fans and other motors should also be considered
A variable flow distribution pumping system to serve the HVAC load is one of the methods to reduce the initial cost and operating cost — depending on the application and the spread area of chilled water load. (speed and pressure modulation is usually accomplished by providing the chilled water pump with a variable frequency drive)
In primary variable flow system, chiller water flow rate is varied in the chiller depending on the load. This enables to work on higher deltaT unlike lower delta T syndrome happening in traditional Primary + Variable secondary systems. The effect is reduction in the cost of procuring water and pumping load, translating into savings in initial cost and as well as the operating cost.
In primary variable flow systems, ...
... evaporator shall be suitable for variable flow operation. i.e. designed to perform proper heat transfer at different water velocities across the tubes.
Generally the flow will be varied between 40% to 100% of the design flow, depending on the load condition. Another important factor to be considered while designing primary variable flow system is that the chilled water flow change rate change should not be more than 2% from the previous flow within 10 Minutes of band. Very fast flow variation to the chiller can lead to operational problems and impact the efficiency of the system and the evaporator as well.
Water flow to the chiller is to be ensured within the chiller operating limits even during the low load operation. So, we need to employ sophisticated control arrangements for the primary variable flow operation.
The diagram below explains the configuration and working principle of the primary variable system.
Chilled water flow is varied according to field demand.
Flow through each chiller is monitored and compared against design through a flow meter.
Chilled water pump speed modulates to maintain a set field DP across the chilled water system i.e. between the supply and return header.
As field demand decreases, field DP will increase.
An increase in field DP above set-point will reduce chilled water pump speed and thereby the flow.
A decrease in field DP below set-point will increase chilled water pump speed and thereby the chilled water flow.
The chilled water bypass valve remains closed until any one of the operating chillers flow rate falls below 80% of design (is also user configurable)
Chilled water bypass will also modulate to maintain a minimum safe flow through the chillers.
If the bypass valve is opened 100% and flow rate across the evaporator is less than the minimum flow required, (in case of low loads) pump speed will be ramped up to maintain safe water flow through the chillers.

For more details visit us
https://in.climaveneta.com/Web/Contacts/India/?utm_source=google&utm_medium=cpc&utm_campaign=Chilled%20Water%20System

Total Views: 162Word Count: 498See All articles From Author

Add Comment

Business Articles

1. Catering Services In Noida For Every Occasion
Author: Catering Services in Noida

2. Leading The Way In Business Continuity Management System (bcms) In Uae And Dubai
Author: kohan

3. Manila Rope: A Versatile Solution For Various Industries In The Uae
Author: yasirsheikh1891

4. Exploring Asian Clothes Online: A Guide For Uk Shoppers
Author: Dazzle and Bloom

5. Maximizing Your Email Marketing Roi: A Comprehensive Guide
Author: tim seifert

6. Spray Paint: The Ultimate Solution For Versatile And Efficient Painting
Author: yakubali7842

7. High-quality Thrust Needle Roller Bearings: Essential For Reliable Performance
Author: psbearings

8. Web Design Company In Coimbatore
Author: cp

9. Top Needle Roller Bearing Manufacturer: Quality You Can Rely On
Author: psbearings

10. Discover The Best Rfid Tags For Your Industry Needs At Id Tech Solutions
Author: Shivam Kumar

11. Translation Company In India
Author: Lingosolution

12. Why Perlau Gwyn Dental Care Is The Top Choice For Dentists In Cardiff And Teeth Whitening Services
Author: Rebecca Brown

13. Hybrid Inverters & Their Diverse Applications
Author: blogswalaindia

14. The Role Of Solar Panels In Sustainable Living
Author: blogswalaindia

15. Solar Energy And Battery Storage: What You Need To Know
Author: blogswalaindia

Login To Account
Login Email:
Password:
Forgot Password?
New User?
Sign Up Newsletter
Email Address: