Variable Primary Flow Chilled Water System

The advancement in technology for HVAC controls applied to chilled-water systems makes it possible to reduce the environmental impact and operating costs.
Chillers are the biggest power consuming equipment in the chiller system but other equipment such as pumps, cooling towers and or dry coolers, Cooling tower fans and other motors should also be considered
A variable flow distribution pumping system to serve the HVAC load is one of the methods to reduce the initial cost and operating cost — depending on the application and the spread area of chilled water load. (speed and pressure modulation is usually accomplished by providing the chilled water pump with a variable frequency drive)
In primary variable flow system, chiller water flow rate is varied in the chiller depending on the load. This enables to work on higher deltaT unlike lower delta T syndrome happening in traditional Primary + Variable secondary systems. The effect is reduction in the cost of procuring water and pumping load, translating into savings in initial cost and as well as the operating cost.
In primary variable flow systems, ...
... evaporator shall be suitable for variable flow operation. i.e. designed to perform proper heat transfer at different water velocities across the tubes.
Generally the flow will be varied between 40% to 100% of the design flow, depending on the load condition. Another important factor to be considered while designing primary variable flow system is that the chilled water flow change rate change should not be more than 2% from the previous flow within 10 Minutes of band. Very fast flow variation to the chiller can lead to operational problems and impact the efficiency of the system and the evaporator as well.
Water flow to the chiller is to be ensured within the chiller operating limits even during the low load operation. So, we need to employ sophisticated control arrangements for the primary variable flow operation.
The diagram below explains the configuration and working principle of the primary variable system.
Chilled water flow is varied according to field demand.
Flow through each chiller is monitored and compared against design through a flow meter.
Chilled water pump speed modulates to maintain a set field DP across the chilled water system i.e. between the supply and return header.
As field demand decreases, field DP will increase.
An increase in field DP above set-point will reduce chilled water pump speed and thereby the flow.
A decrease in field DP below set-point will increase chilled water pump speed and thereby the chilled water flow.
The chilled water bypass valve remains closed until any one of the operating chillers flow rate falls below 80% of design (is also user configurable)
Chilled water bypass will also modulate to maintain a minimum safe flow through the chillers.
If the bypass valve is opened 100% and flow rate across the evaporator is less than the minimum flow required, (in case of low loads) pump speed will be ramped up to maintain safe water flow through the chillers.
For more details visit us
https://in.climaveneta.com/Web/Contacts/India/?utm_source=google&utm_medium=cpc&utm_campaign=Chilled%20Water%20System
Add Comment
Business Articles
1. Elevate Your Style With Custom Tuxedos From La Rukico – The Best Bespoke Tailor In NycAuthor: La Rukico Custom Tailor
2. Short Term Loans Uk Direct Lender: The Initial And Final Step In Getting Quick Funding
Author: Helen Clark
3. Factors To Consider When Choosing Nano Ceramic Roofing Tiles In Andhra Pradesh
Author: Danish Fabrication
4. Short Term Loans Uk: Apply Online For A Loan From A Direct Lender
Author: Sarah Ferguson
5. How Appkodes Built Their Own Way To Revolutionize The Airbnb Clone
Author: John Daniel M
6. The Real Deal: What Actually Works For Seo Managers In 2025
Author: Rene
7. Unlocking The Advantages Of E-waste Management Awareness Training
Author: Emma
8. Trimbakeshwar Temple Kaal Sarp Puja | Shree Trimbakeshwar
Author: Rakesh Guruji
9. Mandatory Procedures In Iso 15378 Documents: A Comprehensive Overview
Author: John
10. Concrete Sealers With Corrosion Inhibitors: Enhancing Durability And Longevity
Author: Ivar
11. Top-rated Restroom Cubicles – Installations & Maintenance
Author: super creations
12. Your Trusted Real Estate Agents In Bihar - Bhushan Realtors Pvt. Ltd
Author: Bhushan Realtors
13. Iron Casting Company In India: Aqeel Industries
Author: Aqeel Industries
14. How Many Days Do You Need To Explore Panama? Panama Mission India
Author: Panama Mission india
15. Mg Hector Price In Chennai: A Complete Guide
Author: balaji